NG 1000 DC Power Supply and DC/DC Converter

  • Full 2-port isolation
  • Stabilized and short circuit proof
  • DIN rail mounting TS35
  • DC Power Supply Input: 230 VAC ± 10 %
  • Available Outputs:

  - NG1000-1-0: 5..12 VDC; max. 250mA

 - NG1000-2-0: 12..24 VDC; max.150 mA

 - NG1000-3-0: 5..24 VDC; max. 1 A

 - NG1000-4-0: 5..24 VDC; max. 2 A

 

  • DC/DC Converter Supply Voltage: 24 VDC to 220 VDC
  • Available Outputs:

  - 5..24 VDC max. 1 A

 - 5..24 VDC max. 2 A

DR DC Power Supply

  • Full 2-portisolation
  • Supply voltage :115 / 230 V AC
  • output voltage: 24V DC
  • Outputcurrent: 3A up to 10 A
  • stabilized andshort circuit proof
  • Protection class: IP20
  • DIN railmounting TS35

DPP15 DC Power Supply

  • Full 2-portisolation
  • Supply voltage:85..264 V AC or 90..375 V DC
  • Adjustable output voltage: 22.5 to 28.5 V DC
  • Current up to 0.6A
  • stabilized andshort circuit proof
  • Protection class: IP20
  •  DIN rail mounting TS35

PSDR 24 VDC Power Supply Module

  • Compact industrial powersupplies with primary switched-mode regulator technology
  • Low output ripple andadjusted output voltage from 22.5 to 28.5 VDC
  • 100 to 240 VAC power supply
  • Accept 85 to 264 VAC or 90to 350 VDC input voltage range
  • 50 to 60 Hz frequency powersystem
  • 24 VDC ±1% @ (1-2-4 A)output
  • Operating temperature: -25to 60°C
  • Isolation voltage : 3 kV ACat both Input/output
  • Din rail mounting
  • Casing: high impact plastic(black)
  • Protection: IP20 touch safe, Class II

CMCP515 DC Power Supply (24 VDC)

  • DIN Rail mounted power supplies with short circuit protection
  • Input voltage: 85 to 264 VAC, 47 to 63 Hz
  • Output voltage: 24 to 28 VDC
  • Polarity: floating, either positive or negative terminal may be grounded
  • Short circuit, overload and open circuit protection
  • Operating Temperature: -10 to +70°C
  • NEC Class 2 component
  • Hazardous area approvals Class 1, Division 2  

CMCP515 Redundancy Module, 10 Amp @ 24VDC

  • Safe and fast spring-clamp terminals installation
  • Redundancy module for building redundant systems
  • Two 5A inputs, one 10A output
  • Only 0.9V voltage drop between input and output under full load
  • Full output current between -40°C to +60°C
  • 12 to 48 VDC @ 10A output
  • 12 to 48 VDC (+/-25%) input
  • Protection: IP 20  (EN/IEC 60529)
  • Approval for use in hazardous locations Zone 2 Category 3G.
  • Number of ATEX certificate: EPS 09 ATEX 1 236
  • The redundancy module must be built-in in an IP54 enclosure 

COPYRIGHT 2018 Four Star Enterprises Pte.Ltd.  |  All Rights Reserved  |  Designed & Maintained by Web Dreams Pte Ltd